HDPE Corrugated Pipe — Techduto NBR

Cable protection certified to NBR 15715 — 750 N and a service life of over 75 years

Diameters
20–250 mm
Resistance
750 N
Service Life
75+ years
Standard
NBR 15715

Flexible corrugated HDPE conduit compliant with NBR 15715, with a tensile strength of 750 N, an integrated cable guide, and a service life of over 75 years, designed to protect electrical, telecommunications, and fiber-optic cables. Also available in special UV and AC lines formulated for solar power plants.

Need drainage and protection? Check out Techdreno

The Problem

Metal and concrete conduits used to protect cables are susceptible to corrosion in acidic soils, require costly maintenance, and have a limited service life. Their heavy installation requires specialized equipment and larger crews, increasing both costs and project timelines.

The HDPE Corrugated Pipe Solution

Techduto NBR eliminates corrosion, withstands impacts of 750 N, and has a service life of over 75 years. Installation is 35% faster than with metal alternatives—the pipe is lightweight and flexible, and the sleeve and O-ring connections require no special tools. Available in UV-resistant versions for solar power plants and with an integrated cable guide.

Proven Differentials

Special UV and AC lines: engineering polymer formulated for years under the sun at photovoltaic plants—where ordinary pipe fails.

UV

Reinforced anti-UV, not the minimum

All HDPE has anti-UV, but only until it's buried. The UV line adds an extra layer, for years of direct sun under the trackers.

AC

Certified flame-retardant

Certified flame-retardant additive, required at plants and power cabinets. The standard pipe doesn't have it.

Field-proven across Latin America

UV and AC lines at dozens of plants: Brazil, Chile, Argentina, and Mexico.

Above the NBR 15715 standard

Compression up to 750 N and a reinforced additive for years of direct sun.

The solar market is demanding — and it is one of our largest. It is not just any anti-UV. The wrong pipe embrittles and needs replacement within a few years in the field. Techduto's UV and AC lines are built for the real life of solar plants: years of sun, heat, and tight schedules. UV and AC lines — installed at dozens of plants in Brazil, Chile, Argentina, and Mexico.

Technical Specifications

Technical data for HDPE Corrugated Pipe — Techduto NBR

ELN and ELS Lines

GaugeNominal DiameterOuter Diameter (mm)Inner Diameter (mm)Packaging
5/8202016Coils 25–50 m
3/4252520Coils 25–50 m
1323226Coils 25–50 m

NBR Line

GaugeNominal DiameterOuter Diameter (mm)Inner Diameter (mm)Packaging
1.1/44040.530.3Coils 25–100 m / Sticks 6–12 m
1.1/25050.540.7Coils 25–100 m / Sticks 6–12 m
26363.552.3Coils 25–100 m / Sticks 6–12 m
39090.275Coils 25–50 m / Sticks 6–12 m
41009983Coils 25–50 m / Sticks 6–12 m
411011194Coils 25–50 m / Sticks 6–12 m
4.1/2125125104Coils 25–50 m / Sticks 6–12 m
5140140120Coils 25–50 m / Sticks 6–12 m
6160160135Coils 25–50 m / Sticks 6–12 m
8200200170.5Coils 30 m / Sticks 6–12 m
10250246215Coils 30–50 m / Sticks 6–12 m

Advantages & Differentiators

Why Techduto NBR is a leader in cable protection

Load capacity of 750 N

Withstands impacts and compression in harsh soil conditions without deforming.

75+ Years of Service Life

Corrosion-resistant, chemically resistant, and dimensionally stable.

35% Faster Installation

Lightweight, flexible, and featuring quick-connect fittings with sleeves and O-rings.

Reinforced UV Line

An extra layer of anti-UV additive, for years of sun at solar plants — far beyond the minimum anti-UV of an ordinary pipe.

AC Flame-Retardant Line

Certified flame-retardant additive, for the fire safety required at solar plants and power installations.

In accordance with NBR 15715

ABNT certification that guarantees standardized dimensions, strength, and quality.

25% Less Maintenance

Eliminates the need for periodic replacement and corrosion repairs throughout its entire service life.

Applications

Where HDPE Corrugated Pipe makes a difference

Frequently Asked Questions

Common questions about HDPE Corrugated Pipe — Techduto NBR

The NBR-lined HDPE pipe eliminates corrosion, withstands impacts of up to 750 N, and has a service life of over 75 years. Metal pipes corrode in aggressive soils and require constant maintenance. Installation of HDPE pipes is 35% faster.
Yes — it is one of our largest applications. The special UV and AC lines are already installed at dozens of plants in Brazil, Chile, Argentina, and Mexico, protecting cables with sun and flame resistance far beyond the standard pipe.
It does, but only a minimal amount — just enough to protect the pipe during transport and construction, until it is buried. That protection was not designed for years of direct sun exposure. At solar plants, where the pipe spends its service life exposed in the shaded areas under the trackers, use the UV line, with a reinforced additive formulated exactly for that.
The NBR line complies with standard 15715 and is robust for buried use. The UV line has an extra layer of anti-UV additive for prolonged sun exposure. The AC line carries a certified flame-retardant additive, for environments where fire safety is critical. UV and AC were developed specifically for photovoltaic plants.
Yes. The corrugated conduit protects fiber-optic, telecommunications, and electrical cables. The integrated cable guide (for sizes 40 mm and larger) makes it easier to feed cables through during installation.
The product line ranges from 20 mm to 250 mm, available in coils or bars depending on the diameter. Sizes ranging from 5/8 inch to 10 inches cater to everything from residential installations to large-scale infrastructure projects.
Yes, starting at a diameter of 40 mm, all pipes come with a factory-installed cable guide, making it easy to thread cables through without the need for special tools.
The product complies with ABNT NBR 15715, which specifies requirements for dimensions, impact resistance (up to 750 N), and quality for HDPE corrugated conduits intended for cable protection.

Need help with your project?

Talk to our technical team and get a tailored proposal.

Talk to a specialist